- Characteristics
- Efficiency: 96.1%
- Input power factor: 0.63
- Input operating voltage (maximum): 300 V
- Input operating voltage (minimum): 140 V
- Output frequency: 50/60 Hz
- Automatic Voltage Regulation (AVR): Yes
- Maximum configurable power: 0.5 kVA
- Input frequency: 50/60 Hz
- Overvoltage protection: Yes
- UPS topology: Line-interactive technology
- Impact Energy Rating: 273 J
- Waveform: Sine
- Noise level: 40 dB
- Audible alarm modes: Alarm when running on battery, Low battery alarm
- Audible alarm: Yes
- Actual power: 300 W
- Design
- Cable length: 1.5 m
- Product color: Black
- LEDs: Battery Replacement
- IP protection class: IP20
- Layout: Tower
- Weight and dimensions
- Product weight: 4.2 kg
- Product depth: 310 mm
- Product height: 138 mm
- Product width: 98 mm
- Working conditions
- Temperature range (operation): 0 - 40 °C
- Permissible operating altitude (above sea level): 0 - 3000 m
- Temperature range (storage): -15 - 40 °C
- Permissible relative humidity: 0 - 95%
- Permissible altitude (above sea level): 0 - 3000 m
- Relative humidity range: 0 - 95%
- Packaging data
- Package height: 222 mm
- Package width: 142 mm
- Package contents
- Management card included: No
- Certificates
- Certificates of conformity: RoHS
- Ports and interfaces
- Number of Ethernet LAN ports (RJ-45): 2
- Number of network sockets: 3 x network socket
- SmartConnect Port: No
- SmartSlot: No
- Plug: C14 panel
- Number of IEC output jumpers: 1
- AC output types: C13 panel
- Cabling technology: 10/100/1000Base-T(X)
- Battery
- Battery voltage: 12 V
- Battery type: Lead acid (VRLA)
- Battery life (max): 5 years
- Charging time: 8 h
- Automatic battery test: Yes
- Logistics data
- Harmonized System (HS) code: 85078000
- Safety warning
- Warnings
- Keep away from sources of fire and water.
- Do not disassemble the device housing, as this may result in electric shock.
- The device should be used in well-ventilated areas to avoid overheating.